Keyless entry system инструкция по подключению
If YES, then continue. Next, test the by-pass button. If you have a by-pass button manual open does pressing it open the door?
Press Start on the keypad. If not, Contact Technical Support. Try entering an ID code. Press Start then enter an ID Code then press Open.
Does the door open? If YES, then Contact Technical Support. If not, then it is likely a problem with the door circuit wiring.
If not, meaning the door still does not open, then the problem is likely to be in the door circuit. Then, test the Relay Box. Locate the connections labeled Door Control Circuit on the relay box.
These connections are labeled NC, C and NO. Wires should be connected to two of the three terminals. Make a note of the terminals to which the wires are attached. Next, carefully remove these two low Keyless entry system инструкция по подключению wires from the Door Control Circuit. If the wires were attached to the NO and C terminals as in the image, typical for a standard electric door strike then touch them together.
If the resistance DID change then the problem is not likely Keyless entry system инструкция по подключению be with the relay box.
If the wires were attached to the NC and C terminals typical for a magnetic lock does removing them from the Relay Box cause the door to open? At this point, further testing of the Relay Box using a handheld Multimeter may be appropriate. Make sure the wires connected to the NC, C or NO terminals have been removed. Place one end of the voltmeter into the C terminal and the other into either the NO typical for a standard electric door strike or NC terminal typical for a magnetic lock.
Electrical Connections — Use Caution. Trouble shooting Keyless entry system инструкция по подключению Keyless Entry System door circuit may involve exposure to low voltage electrical current. Begin by testing the keypad.
Have someone go to the keypad and press Start, enter an ID Code, and then press Open. Does the resistance shown on the multimeter change?. For a standard electric door strike it should go from infinite no current to zero full current flowing. For a magnetic lock it would be the reverse going from zero full current flowing to infinite resistance no current. If the resistance did NOT change, then Contact Technical Support.